P1551
P1551, P1552 BATTERY CURRENT SENSORDescription
The power generation voltage variable control enables fuel consumption to be decreased by reducing the engine load which is caused by the power generation of the generator. The battery current sensor is installed to the battery cable at the negative terminal. The sensor measures the charging/discharging current of the battery. Based on the sensor signal, ECM judges whether or not the power generation voltage variable control is performed. When performing the power generation voltage variable control, ECM calculates the target power generation voltage based on the sensor signal. And ECM sends the calculated value as the power generation command value to IPDM E/R.
CAUTION: Do not connect the electrical component or the ground wire directly to the battery terminal. The connection causes the malfunction of the power generation voltage variable control, and then the battery discharge may occur.
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
Step 1-2:
Diagnosis Procedure
Step 1-5:
Step 5 (Continued)-11:
Step 11 (Continued)-14:
Component Inspection