Knock Sensor: Testing and Inspection
Knock Sensor Connector:
1. Disconnect Knock Sensor sub-harness connector.
Knock Sensor Test:
2. Check continuity between terminal (a) and ground. Continuity should exist.
If no continuity exists, inspect Knock Sensor sub-harness.
Code 34
If sub-harness is OK, replace Knock Sensor.