Main Relay (Computer/Fuel System): Testing and Inspection
Work Flow
NOTE:
^ When LCU connectors are disconnected for more than 1 minute such as during trouble diagnosis, the "disconnected" data will be memorized by the BCM (Body Control Module). Therefore, after reconnecting the LCU connectors, erase the memory.
^ To erase the memory, perform the procedure below.
Erase the memory with CONSULT or turn the ignition switch to "OFF" position and remove 7.5 A fuse (No. (56) located in the fuse and fusible link box).
Power Supply Circuit Check
Ground Circuit Check
Data Lines Circuit Check
Data Lines Open Circuit Check
NOTE: When checking data line circuit, disconnect BCM and all LCU Connectors.
1. Disconnect BCM and LCU connectors
2. Check continuity between BCM and LCU terminals.
Data Lines Short Circuit Check
1. Disconnect BCM and LCU connectors
2. Check continuity between BCM and body ground.
3. Check voltage between BCM terminal and body ground.