Programming and Relearning
Enter the identity (ID) code manually when:^ remote controller or Body Control Module (BCM) is replaced.
^ an additional remote controller is activated.
Procedure 1 (Without CONSULT)
NOTE
^ If you need to activate more than two additional new remote controllers, repeat the procedure "Additional ID code entry" for each new remote controller.
^ If the same ID code that exists in the memory is input, the entry will be ignored.
^ Entry of maximum four ID codes is allowed and any attempt to enter more will be ignored.
Procedure 2 (With CONSULT)
1. Turn ignition switch "OFF".
2. Connect "CONSULT" to Data link connector.
3. Turn ignition switch "ON".
4. Touch "START".
5. Touch "IVMS".
6. Touch "REMOTE CONT ID REG".
7. Touch "START".
^ At this time, the original ID codes are eliminated. (Then power door lock will lock, unlock, and the hazard warning lamp will flash twice.)
8. Push lock button on the new remote controller once.
^ At this time, the new ID code is entered. (Then power door lock will lock, unlock, and the hazard warning lamp will flash twice.)
Additional ID code entry
9. Push lock button on the additional remote controller once.
^ Maximum of four ID are able to be entered. Any attempt to enter more will be ignored.
10. Touch "END".
^ After entering the identity (ID) code, check the operation of multi-remote control system.
NOTE
^ If you need to activate more than two additional new remote controllers, repeat the procedure "Additional ID code entry" for each new remote controller.
^ If the same ID code that exists in the memory is input, the entry will be ignored.
^ Entry of maximum four ID codes is allowed and any attempt to enter more will be ignored.