Code 1005
COMPONENT DESCRIPTION
The EGRC-solenoid valve responds to signals from the ECM. When the ECM sends an ON (ground) signal, the coil in the solenoid valve is energized. The vacuum signal passes through the solenoid valve. The signal then reaches the EGR valve. When the ECM sends an OFF signal, a plunger will then move to cut the vacuum signal from the intake manifold collector to the EGR valve.
CONSULT Reference Value in Data Monitor Mode
Specification data are reference values.
ECM Terminals and Reference Value
Specification data are reference values and are measured between each terminal and 43 (ECM ground).
ON BOARD DIAGNOSIS LOGIC
DTC CONFIRMATION PROCEDURE
NOTE: If "DTC Confirmation Procedure" has been previously conducted, always turn ignition switch "OFF" and wait at least 5 seconds before conducting the next test.
With CONSULT
1. Turn ignition switch "ON".
2. Select "DATA MONITOR" mode with CONSULT and wait at least 5 seconds.
3. If 1st trip DTC is detected, go to "Diagnostic Procedure".
With GST
1. Turn ignition switch "ON" and wait at least 5 seconds.
2. Select "MODE 7" with GST.
3. If 1st trip DTC is detected, go to "Diagnostic Procedure".
Without Scan Tools
1. Turn ignition switch "ON" and wait at least 5 seconds.
2. Turn ignition switch "OFF" and wait at least 5 seconds.
3. Turn ignition switch "ON" and perform "Diagnostic Test Mode II (Self-diagnostic results)" with ECM.
4. If 1st trip DTC is detected, go to "Diagnostic Procedure".
WIRING DIAGRAM
1 CHECK POWER SUPPLY:
2 DETECT MALFUNCTIONING PART:
3 CHECK OUTPUT SIGNAL CIRCUIT:
4 DETECT MALFUNCTIONING PART:
5 CHECK EGRC-SOLENOID VALVE:
6 CHECK INTERMITTENT INCIDENT:
DIAGNOSTIC PROCEDURE
COMPONENT INSPECTION
Check air passage continuity.
With CONSULT
Perform "EGRC SOLENOID VALVE" in "ACTIVE TEST" mode.
Without CONSULT
If NG or operation takes more than 1 second, replace solenoid valve.