Charge Lamp/Indicator: Description and Operation
System DescriptionWith the ignition switch in the ON or START position, power is supplied
- through 7.5 A fuse (No. [4], located in the fuse block (J/B)]
- to combination meter terminal (41).
Ground is supplied
- to combination meter terminal (39) and
- A/T device (OD control switch) terminal (2)
- through body grounds (M14) and (M47).
Ground is supplied
- to fuel level sensor unit terminal (4)
- through ECM terminal (129).
Ground is supplied
- seat belt buckle switch terminal (14)
- through body grounds (B22) and (B35).
Ground is supplied
- to brake fluid level switch terminal (2) and
- washer level switch terminal (2)
- through body grounds (E22) and (E36).
CHARGE WARNING LAMP
During prove out or when a alternator malfunction occurs, ground is supplied
- to combination meter terminals (31) and (40)
- from alternator terminal (3).
With power and ground supplied, the charge warning lamp and brake lamp illuminate.