Auxiliary Mechanism: Temperature Setting Trimmer
AUXILIARY MECHANISM: TEMPERATURE SETTING TRIMMER
The trimmer compensates for differences in range of ±3 °C (±6 °F) between temperature setting (displayed digitally) and temperature felt by driver.
Operating procedures for this trimmer are as follows:
- Begin Self-diagnosis STEP 5 mode.
Step-By-Step Procedure
- Press [FAN] UP switch to set system in auxiliary mode.
- Display shows 61 in auxiliary mechanism.
It takes approximately 3 seconds.
- Turn the temperature dial as desired. Temperature will change at a rate of 0.5 °C (1.0 °F) each time a dial is turned.
When battery cable is disconnected, trimmer operation is canceled. Temperature set becomes that of initial condition, i.e. 0 °C (0 °F).