Vehicle Immobilizer System
CONSULT-II INSPECTION PROCEDURE1. Turn ignition switch OFF.
2. Insert IVIS (NATS) program card into CONSULT-II.
Program card : NATS (AEN02B)
3. Connect CONSULT-II and "CONSULT-II CONVERTER" to data link connector.
4. Turn ignition switch ON.
5. Touch "START".
6. Perform each diagnostic test mode according to each service procedure.
NOTE: When any initialization is performed, all ID numbers previously registered will be erased and all IVIS (NATS) electronic keys must be registered again. The engine cannot be started with an unregistered key. The system will show "DIFFERENCE OF KEY" or "LOCK MODE" as a self-diagnostic result on the CONSULT-II screen.
For further information, see the CONSULT-II Operation Manual, IVIS/NVIS.
Results Item Chart