CONSULT-II Basic Operation Procedure
CONSULT-II BASIC OPERATION PROCEDURE1. With the ignition switch OFF, connect CONSULT-II and CONSULT-II CONVERTER to the data link connector on vehicle side, and turn the ignition switch ON.
2. Touch START (NISSAN BASED VHCL).
3. Touch IVMS.
If IVMS is not indicated, go to GI-38, "CONSULT-II Data Link Connector (DLC) Circuit". Data Link Connector Schematic
4. Check the model specification, touch either WITH SUNROOF WITHOUT SUNROOF.
5. Touch OK. If the selection is wrong, touch CANCEL.
6. Select the desired part to be diagnosed on the SELECT TEST ITEM screen.