Door/Trunk Ajar Indicator/Lamp: Description and Operation
DOOR WARNING LAMPDoor waning lamp is controlled by BCM.
When one of the doors is opened, ground is supplied to the BCM terminals 33, 37,142 and 143.
And then ground is supplied
- to combination meter terminal 49
- from BCM terminal 111