Vehicle Immobilizer System
CONSULT-IICONSULT-II INSPECTION PROCEDURE
1. Turn ignition switch OFF.
2. Insert IVIS (NATS) program card into CONSULT-II.
Program card : NATS (AEN02C)
3. Connect CONSULT-II and CONSULT-II CONVERTER to data link connector.
4. Turn ignition switch ON.
5. Touch "START".
6. Touch "OTHER".
7. Select "NATS V.5.0".
If "NATS V5.0" is not indicated, go to "Data Link Connector (DLC) Circuit". Diagnostic Aids
8. Perform each diagnostic test mode according to each service procedure.
For further information, see the CONSULT-II Operation Manual NATS-IVIS/NVIS.