With Manufacturer's Scan Tool (CONSULT II)
CONSULT-II INSPECTION PROCEDURE1. Turn ignition switch OFF.
2. Connect "CONSULT-II" and "CONSULT-II CONVERTER" to data link connector, which is located under LH dash panel near the hood opener handle.
3. Turn ignition switch ON.
4. Touch "START (NISSAN BASED VHCL)".
5. "Touch ENGINE".
If "ENGINE" is not indicated, go to "CONSULT-II" Data Link Connector (DLC) Circuit". Diagnostic Aids
6. Perform each diagnostic test mode according to each service procedure.
For further information, see the "CONSULT-II" Operation Manual.