Remote Keyless Entry System
Work Flow1. Check the symptom and customer's requests.
2. Understand the outline of system.
3. Perform the preliminary check. Refer to BL-71, "Preliminary Check". Remote Keyless Entry System
4. Perform the communication inspection. If CONSULT-II is used, refer to BL-74, "IVMS COMMUNICATION INSPECTION". CONSULT-II Basic Operation Procedure If CONSULT-II is not used, refer to BL-78, "COMMUNICATION DIAGNOSIS". Communication Diagnosis Procedure Is the communication diagnosis result OK?
OK: GO TO step 7.
NG: GO TO step 5.
5. Repair or replace depending on the diagnosis result.
6. Perform the communication diagnosis again. If CONSULT-II is used, refer to BL-74, "IVMS COMMUNICATION INSPECTION". CONSULT-II Basic Operation Procedure If CONSULT-II is not used, refer to BL-78, "COMMUNICATION DIAGNOSIS". Communication Diagnosis Procedure Is communication diagnosis result OK?
OK: GO TO step 7.
NG: GO TO step 5.
7. Referring to Trouble diagnosis chart, repair or replace the cause of the incident. Refer to "Trouble Diagnosis Chart by Symptom".
8. Does the remote keyless entry system operate normally?
YES: GO TO step 9.
NO: GO TO step 7.
9. Inspection end.