C1154
When SHIFT POSITION ERROR Appears in Self-Diagnostic results Display (A/T Models)INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSTIC RESULTS
Check the self-diagnostic results.
Is above displayed in the self-diagnosis item?
YES >> GO TO 2.
NO >> INSPECTION END
2. CHECK DATA MONITOR
1. Connect CONSULT-II and CONSULT-II CONVERTER to data link connector. Start engine.
2. In DATA MONITOR select MAIN SIGNALS and then check select lever position.
OK or NG
OK >> Perform VDC/TCS/ABS control unit self-diagnosis again.
NG >> GO TO 3.
3. CHECK A/T PARK/NEUTRAL POSITION SWITCH
Perform the A/T park/neutral position switch inspection. Refer to AT-108, "DTC P0705 PARK/NEUTRAL POSITION SWITCH". P0705
Do any self-diagnosis items appear?
YES >> Repair the indicated items and perform VDC/TCS/ABS control unit self-diagnosis again.
NO >> Perform VDC/TCS/ABS control unit self-diagnosis again.