Air Flow Meter/Sensor: Service and Repair
AIR CLEANER AND AIR DUCTEM-17 Component:
Removal and Installation
REMOVAL
1. Remove engine room cover (RH and LH).
2. Remove air duct (inlet).
3. Disconnect mass air flow sensor harness connector.
4. Disconnect PCV hose.
5. Remove air cleaner case/mass air flow sensor assembly and air duct/air hose disconnecting their joints.
^ Add marks as necessary for easier installation.
6. Remove mass air flow sensor from air cleaner case, as necessary.
CAUTION:
Handle mass air flow sensor with the following cares.
^ Never shock mass air flow sensor.
^ Never disassemble mass air flow sensor.
^ Never touch mass air flow sensor.
INSTALLATION
Note the following, and install in the reverse order of removal.
^ Align marks. Attach each joint. Screw clamps firmly.