Aiming Adjustment
LASER BEAM AIMING ADJUSTMENT
Aiming Adjustment
CAUTION:
Perform all necessary work for laser beam adjustment until the adjustment completes as shown in the procedure. If the procedure does not complete, the ICC system is inoperable.
1. Connect CONSULT-III and select "Work Support" of "ICC".
2. Select "LASER BEAM ADJUST".
3. Touch "Start".
CAUTION:
If the adjustment screen does not appear on the CONSULT-III screen in 10 seconds, after touching "LASER BEAM ADJUST" screen, the following causes may be considered:
- ICC target is not set accurately.
- There is not enough space beside the ICC target.
- The laser beam aiming adjustment exceeds its proper installation range.
- Deformation of vehicle body.
- Deformation of unit.
- Deformation of bracket.
- The area is not suitable for the adjustment work.
- ICC sensor integrated unit is not clean.
- The ICC system warning lamp illuminates.
4. After the CONSULT-III displays "ADJUST THE VERTICAL OF LASER BEAM AIMING" turn the up-down direction adjusting screw until "U/D CORRECT" value is set in the range of �4.
CAUTION:
Turn the screw slowly. The value change on display is slower than actual movement of the ICC sensor integrated unit. Wait for 2 seconds every time the screw is turned half a rotation.
NOTE:
Turning the screw (A) clockwise directs the laser beam downward (B). The laser beam directs upward (C) when turning screw counterclockwise.
5. When "U/D CORRECT" value indicates �4, confirm that the margin of value remains within �4 at least for
2 seconds with no equipment or hand touching the ICC sensor integrated unit.
When "COMPLETED THE VERTICAL AIMING OF LASER BEAM" appears on screen, touch "END".
CAUTION:
Be sure that the margin of "U/D CORRECT" is within �4 after leaving with ICC sensor integrated unit for 2 seconds or more.
6. Confirm that "ADJUSTING AUTOMATIC HORIZONTAL LASER BEAM AIMING" is on screen and wait for a while (maximum: 10 seconds).
7. Confirm that "Normally Completed" is displayed on CONSULT-III and close the aiming adjustment procedure by touching "End".
CAUTION:
Perform all the procedures once "LASER BEAM ADJUST" mode is entered in CONSULT-III. When the procedure is discontinued, the ICC system is inoperable.
CHECK AFTER THE ADJUSTMENT
Test the ICC system operation by ICC system running test. Refer to ICC.