Automatic Intake Control (Exhaust Gas / Outside Odor Detecting Mechanism)
FOREST AIR SYSTEM : Automatic Intake Control (Exhaust Gas / Outside Odor Detecting Mechanism)
DESCRIPTION
In addition to air inlet automatic control of automatic air conditioning system, A/C auto amp. controls automatically air inlet according to signal from exhaust gas/outside odor detecting sensor, so that unpleasant outside odor does not enter in passenger room.
OPERATION DESCRIPTION
- Air inlet switches to recirculation when exhaust gas or outside odor is detected while FOREST switch is ON.
After that, air inlet switches to fresh air intake when exhaust gas or outside odor becomes not detectable.
- Control status is displayed on "Forest Air Info" screen. Switch Name And Function.
NOTE:
- Sensitivity of exhaust gas / outside odor detecting sensor can be changed by "Outside/Inside Air Mix" in "Forest Air Setting" menu. Menu Displayed By Pressing Each Switch.
- Automatic intake control (exhaust gas / outside odor detecting mechanism) does not operate when ambient temperature is -2�C (28�F) or less. In this case, control is only for control of automatic air inlet of automatic air conditioning system.