Intelligent Key
INTELLIGENT KEY
Component Function Check
1. CHECK FUNCTION
1.Select "INTELLIGENT KEY" of "BCM" using CONSULT.
2.Select "RKE OPE COUN1" in "DATA MONITOR" mode.
3.Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES- Intelligent Key is OK.
NO- .
Diagnosis Procedure
1. CHECK INTELLIGENT KEY BATTERY
Check by connecting a resistance (approximately 300 Ohm) so that the current value becomes approximately 10 mA.
Is the measurement value within the specification?
YES- Replace Intelligent Key.
NO- Replace Intelligent Key battery.
Special Repair Requirement
Refer to CONSULT Operation Manual NATS-IVIS/NVIS.