Work Procedure
STROKE SENSOR 0 POINT LEARNING
Work Procedure
CAUTION:
Make sure to use CONSULT when performing stroke sensor 0 point learning. (It cannot be performed by any means other than CONSULT.)
1. VEHICLE CONDITION
1.Stop the vehicle.
2.Turn the ignition switch OFF.
- GO TO 2.
2. CHECK 12V BATTERY
Check the 12V battery.Testing and Inspection.
Is the inspection result normal?
YES- GO TO 3.
NO- Charge or replace the 12V battery. Procedures. GO TO 3.
3. CHECKING INSTALLATION CONDITIONS OF BRAKE COMPONENTS
Check the installation conditions of brake components.
Is the inspection result normal?
YES- GO TO 4.
NO- Repair or replace error-detected parts and GO TO 4.
4. CHECK BRAKE PEDAL
Check each brake pedal height. Adjustments.
Is the inspection result normal?
YES- GO TO 5.
NO- Adjust each brake pedal height. Adjustments. GO TO 5.
5. PERFORM THE SELF-DIAGNOSIS
With CONSULT
1.Turn the ignition switch OFF to ON.
CAUTION:
Never set the vehicle to READY/Never start the engine.
2.Repeat step 1 two times or more.
CAUTION:
Be sure to wait for 5 seconds or more after turning the ignition switch OFF.
3.Turn the ignition switch OFF.
4.Close all doors including the trunk lid, and wait outside of vehicle for 5 minutes or more.
5.Turn the ignition switch ON.
CAUTION:
Never set the vehicle to READY/Never start the engine.
6.Erase self-diagnosis result of "BRAKE".
CAUTION:
Turn the ignition switch OFF and wait 5 minutes or more after erase self-diagnosis result.
7.Depress brake pedal by 100 mm (3.94 in) or more, and hold the position for 5 seconds or more.
8.Release brake pedal.
9.Repeat steps 7 to 8 three times.
10.Perform "BRAKE" self-diagnosis.
Is a malfunction detected?
YES- Check the DTC. Testing and Inspection. GO TO 6.
NO- GO TO 6.
6. PERFORM PEDAL STROKE SENSOR 0 POINT LEARNING
With CONSULT
1.Turn the ignition switch OFF and wait for 10 seconds.
2.Turn the ignition switch ON.
CAUTION:
Never set the vehicle to READY/Never start the engine.
3.Select "BRAKE", "WORK SUPPORT" and "STROKE SENSOR 0 POINT LEARNING" according to this order.
CAUTION:
Never depress brake pedal.
4.Touch "START".
Was either "COMPLETED" or "The operation is incomplete. Try again after confirming the operation condition." displayed?
"COMPLETED"-Touch the "END". GO TO 7.
"The operation is incomplete. Try again after confirming the operation condition."-GO TO 2.
7. CHECK DATA MONITOR
With CONSULT
Select "BRAKE", "DATA MONITOR" and "STROKE SEN 1 OUTPUT VOLT" according to this order. Check that this signal is within the specified value.
Is the inspection result normal?
YES- GO TO 8.
NO- GO TO 1.
8. ERASE SELF-DIAGNOSIS MEMORY
With CONSULT
1.Turn the ignition switch OFF, and then turn it ON again.
CAUTION:
Be sure to perform the operation above.
2.Erase self-diagnosis result of "BRAKE".
CAUTION:
Turn the ignition switch OFF and wait 5 minutes or more after erase self-diagnosis result.
Are the memories erased?
YES- INSPECTION END
NO- Check the items indicated by the self-diagnosis.