GR8 Multitasking Battery Diagnostic Station Setup
GR8 Multitasking Battery Diagnostic Station Setup1. Connect the battery tester/charger to the 12 V battery, positive cable first.
2. Plug in the battery tester/charger (AC voltage supply), and then turn ON the battery tester/charger.
3. Select the preferred language, and then depress NEXT.
4. Select the USER, and then depress NEXT.
5. Confirm the USER, and then depress NEXT.
6. Select System Test, and then depress the "down" arrow.
7. Select the Manual icon, and then depress NEXT.
8. Select REGULAR FLOODED, and then depress NEXT.
9. Select LIMIT VOLTAGE, and then depress NEXT.
10. Set MIN VOLTAGE to 12.40 volts, and then depress NEXT.
^ Use the arrows to raise and lower the voltage setting.
11. Set the charging time for 40 minutes, and then depress NEXT.
12. Wait for the system to go through Test mode and Advanced Test mode.
13. Continue with the reprogramming procedure.
NOTE:
For further details on battery tester/charger connection and set-up, refer to the battery tester/chargers instruction manual.