Heating and Air Conditioning: Tools and Equipment

Standard for Recovery/Recycle/Recharge Equipment


Feature Requirement

Recovery rate 0,014 - 0,062 cubic. m/min. (1,36 kg in 20 minutes)
Cleaning capability 15 parts per million (ppm) moisture; 4000 ppm oil; 330 ppm non condensable gases in air
Oil separator With hermetic compressor and automatic oil return
Moisture indicator Sight glass type, sensitive to 15 ppm minimum
Vacuum pump 2 stage 0,07 - 0,127 cubic. m/min.
Filter Replaceable with moisture indicator
Charge Selectable charge weight and automatic delivery
Hoses Dedicated HFC 134A port connections.
Charge pressure Heating element to increase pressure