D20: Check Harness Short Core to Core
Measure the insulation resistance between EM012/017 and EM012/022.
- Is the resistance > 10 M ohms?
Yes
Reconnect all plugs
GO to D21 D21: End
Check harness/connector EM012, EM015 and EM022 for corrosion, bent/pushed back pins.
Repair as required and reconnect plug(s).