A12: Check For Short to B+ - (#1 Control Module)
NOTE: Departure from previous logic. YES now indicates a fault instead of NO.
Remove fuse F18
With EM012, EM013 and EM027 disconnected, measure the voltage between ground EM027/009 and in turn:
EM013/026
EM013/033
EM013/032
EM013/023
- Any voltage > 0 (zero)V?
Yes
Inspect connectors EM013 and EM027 for bent/pushed back pins or locate and repair the harness. Test the system for normal operation.
No
Do not replace fuse F18
GO to A13 A13: Check For Short to B+ - (#2 Control Module)