Operation CHARM: Car repair manuals for everyone.

Upstream Oxygen Sensor RH




Removal


1. WARNING:
ENSURE THAT THE EXHAUST CATALYST ARE COLD BEFORE COMMENCING WORK



Disconnect the battery ground lead.







2. NOTE: LH shown, RH access equal


From inside the engine compartment, release the relevant sensor(s) multiplug from its mounting bracket and disconnect the plug.

3. To gain access to the sensor(s) the front muffler assembly must be displaced for clearance.







4. NOTE: LH shown, RH access equal


Using a suitable crowfoot wrench remove the sensor.

Installation
1. Fitting is the reverse of the removal procedure, noting that a new sealing washer should be used.







2. Tighten the sensor to specification.
3. Make good the exhaust seals.