System Specifications
Specification for Recovery/Recycle/Recharge EquipmentNOTE: ppm = parts per million
Feature | Requirement |
Recovery rate | 0,014-0,062 m(cube)/min. (1,36 kg in 20 minutes) |
Cleaning capability | 15 ppm moisture; 4000 ppm oil; 330 ppm non condensable gases in air |
Oil separator | With hermetic compressor and automatic oil return |
Moisture indicator | Sight-glass type, sensitive to 15 ppm minimum |
Vacuum pump | Two-stage 0,07-0,127 m(cube)/min. |
Filter | Replaceable, with moisture indicator |
Charge | Selectable charge weight and automatic delivery |
Hoses | Dedicated HFC 134A port connections |
Charge pressure | Heating element to increase pressure |