P0152
K : P0151, P0152, P0153, P1647. LEFT-HAND BANK HO2S
K1 : CHECK THE CONSTANT CIRCUIT OF THE LEFT-HAND BANK HO2S FOR OPEN CIRCUIT
1. Disconnect the HO2S electrical connector EN32.
2. Disconnect the PCM electrical connector EN16.
3. Measure the resistance between EN16, pin 108 (P) and EN32, pin 4 (P)
Is the resistance less than 5 ohms?
Yes
Goto K2
No
REPAIR the circuit. For additional information, refer to the wiring diagrams. CLEAR the DTCs. TEST the system for normal operation.
K2 : CHECK THE CONSTANT CIRCUIT OF THE LEFT-HAND BANK HO2S FOR SHORT TO GROUND
1. Measure the resistance between EN16, pin 108 (P) and GROUND.
Is the resistance less than 10,000 ohms?
Yes
REPAIR the short circuit. For additional information, refer to the wiring diagrams. CLEAR the DTCs. TEST the system for normal operation.
No
Goto K3
K3 : CHECK THE CONSTANT CIRCUIT OF THE LEFT-HAND BANK HO2S FOR SHORT TO BATTERY
1. Connect the PCM electrical connector EN16.
2. Turn the ignition switch to the ON position.
3. Measure the voltage between EN32, pin 4 (P) and GROUND.
Is the voltage greater than 5 volts?
Yes
REPAIR the short circuit. For additional information, refer to the wiring diagrams. CLEAR the DTCs. TEST the system for normal operation.
No
Goto K4
K4 : CHECK THE VARIABLE CIRCUIT OF THE LEFT-HAND BANK HO2S FOR OPEN CIRCUIT
1. Disconnect the HO2S electrical connector EN32.
2. Disconnect the PCM electrical connector EN16.
3. Measure the resistance between EN16, pin 107 (Y) and EN32, pin 3 (Y)
Is the resistance less than 5 ohms?
Yes
Goto K5
No
REPAIR the circuit. For additional information, refer to the wiring diagrams. CLEAR the DTCs. TEST the system for normal operation.
K5 : CHECK THE VARIABLE CIRCUIT OF THE LEFT-HAND BANK HO2S FOR SHORT TO GROUND
1. Measure the resistance between EN16, pin 107 (Y) and GROUND.
Is the resistance less than 10,000 ohms?
Yes
REPAIR the short circuit. For additional information, refer to the wiring diagrams. CLEAR the DTCs. TEST the system for normal operation.
No
Goto K6
K6 : CHECK THE VARIABLE CIRCUIT OF THE LEFT-HAND BANK HO2S FOR SHORT TO BATTERY
1. Connect the PCM electrical connector EN16.
2. Turn the ignition switch to the ON position.
3. Measure the voltage between EN32 pin 3 (Y) and GROUND.
Is the voltage greater than 5 volts?
Yes
REPAIR the short circuit. For additional information, refer to the wiring diagrams. CLEAR the DTCs. TEST the system for normal operation.
No