Body - Sliding Roof Does Not Close Properly
XT501-05X-TYPE
DATE 06/02
Amended 07/02
MODEL
2002 MY
X-TYPE
VIN
C00001-C76168
Sliding Roof Does Not Close Properly/Bounces Open - Loss Of Calibration - Replace Sliding Roof Motor
Remove and destroy Bulletin XT501-05, dated 06/02. Replace with this Bulletin.
Revisions are marked with asterisks.
Issue:
On some 2002 MY X-TYPE vehicles within the above VIN range, customers may experience a condition where the sliding roof may not shut properly and bounces' open when the closed position is reached. Symptoms can become apparent if the ignition is switched off when the sliding roof is in motion.
The sliding roof can be re-calibrated, but the fault can recur. A permanent service fix is to replace the sliding roof motor. A software change in the new (smart) sliding roof motor eliminates this concern, as the position of the sliding roof is continuously stored.
Action:
On a customer complaint basis only, follow the workshop procedure below.
SLIDING ROOF MOTOR REPLACEMENT PROCEDURE
1. Remove overhead console (see Workshop Manual, JTIS CD ROM, section: 501-12).
2. Remove sliding roof opening panel motor securing bolts.
3. Disconnect sliding roof opening panel motor electrical connector.
4. Connect electrical connector to new sliding roof opening panel motor.
5. Install sliding roof opening panel motor securing bolts and tighten to 3 Nm.
6. Install overhead console (see Workshop Manual, JTIS CD ROM, section: 501-12).
SLIDING ROOF LEARNING PROCEDURE
1. * Press the front of the sliding roof rocker switch and hold it until the roof has tilted open fully.
Note:
Sliding roof moves to fully tilted position and stops.
2. Release the switch.
3. Press the front of the sliding roof rocker switch again and continue to hold it until the sliding roof panel briefly pops up higher.
4. Release the switch.
5. Within 5 seconds, press the front of the sliding roof rocker switch again and continue to hold it while the roof panel slides fully open and then closed again and stops.*
6. Release sliding roof rocker switch (sliding roof is now synchronized).
Note:
If the switch is released before the panel reaches the fully closed position, the motor synchronization is not complete. If the motor synchronization has not been completed successfully, the sliding roof moves only in one direction (tilt).
If the power operation fails, the sliding roof can be opened or closed by hand. Remove the roof console to gain access to the drive spindle, insert a 4 mm Allen socket into the drive spindle and turn clockwise to open or counterclockwise to close the sliding roof panel.
Parts Information
Warranty Information:
Warranty claims should be submitted quoting the information found in the table.
This will result in payment of the stated time and, where applicable parts/miscellaneous expense codes as listed.