P0340
C : DTC P0340, P0341: RIGHT-HAND BANK CAMSHAFT POSITION (CMP) SENSOR
C1 : CHECK THE RIGHT-HAND BANK CMP SENSOR FOR CORRECT INSTALLATION
1. Turn the ignition switch to the OFF position.
2. Check the CMP sensor for correct installation.
Is the CMP sensor correctly installed?
Yes
Goto C2
No
INSTALL the CMP sensor correctly. CLEAR the DTCs. TEST the system for normal operation.
C2 : CHECK THE RIGHT-HAND BANK CMP SENSOR FOR FOREIGN DEBRIS
1. Remove the CMP sensor and inspect for foreign debris.
Is the CMP sensor free of foreign debris?
Yes
Goto C3
No
CLEAN the sensor and wheel. INSTALL the sensor. CLEAR the DTCs. TEST the system for normal operation.
C3 : CHECK THE RIGHT-HAND BANK CMP SENSOR SIGNAL WIRE FOR OPEN CIRCUIT
1. Disconnect the PCM electrical connector EN16.
2. Disconnect the CMP sensor electrical connector EN43.
3. Measure the resistance between the CMP sensor electrical connector EN43, pin 1 (O) and the PCM electrical connector EN16, pin 94 (O).
Is the resistance less than 5 ohms?
Yes
Goto C4
No
REPAIR the circuit. For additional information, refer to the wiring diagrams. CLEAR the DTCs. TEST the system for normal operation.
C4 : CHECK THE RIGHT-HAND BANK CMP GROUND WIRE FOR OPEN CIRCUIT
1. Measure the resistance between the CMP sensor electrical connector EN43, pin 2 (B) and the PCM electrical connector EN16, pin 95 (B).
Is the resistance less than 5 ohms?
Yes
Goto C5
No
REPAIR the circuit. For additional information, refer to the wiring diagrams. CLEAR the DTCs. TEST the system for normal operation.
C5 : CHECK THE RIGHT-HAND BANK CMP SENSOR SIGNAL CIRCUIT FOR A SHORT TO GROUND
1. Measure the resistance between the CMP sensor electrical connector EN43, pin 1 (O) and GROUND.
Is the resistance less than 10,000 ohms?
Yes
REPAIR the short to GROUND. For additional information, refer to the wiring diagrams. CLEAR the DTCs. TEST the system for normal operation.
No
Goto C6
C6 : CHECK THE RIGHT-HAND BANK CMP SENSOR GROUND CIRCUIT FOR A SHORT TO GROUND
1. Measure the resistance between the CMP sensor electrical connector EN43, pin 2 (B) and GROUND.
Is the resistance less than 10,000 ohms?
Yes
REPAIR the short to GROUND. For additional information, refer to the wiring diagrams. CLEAR the DTCs. TEST the system for normal operation.
No
Goto C7
C7 : CHECK THE RIGHT-HAND BANK CMP SENSOR SIGNAL CIRCUIT FOR A SHORT TO BATTERY
1. Turn the ignition switch to the ON position.
2. Measure the voltage between the CMP sensor electrical connector EN43, pin 1 (O) and GROUND.
Is the voltage greater than 1 volt?
Yes
REPAIR the short to battery. For additional information, refer to the wiring diagrams. CLEAR the DTCs. TEST the system for normal operation.
No
Goto C8
C8 : CHECK THE RIGHT-HAND BANK CMP SENSOR GROUND CIRCUIT FOR A SHORT TO BATTERY
1. Turn the ignition switch to the ON position.
2. Measure the voltage between the CMP sensor electrical connector EN43, pin 2 (B) and GROUND.
Is the voltage greater than 1 volt?
Yes
REPAIR the short to battery. For additional information, refer to the wiring diagrams. CLEAR the DTCs. TEST the system for normal operation.
No
INSTALL a new CMP sensor. CLEAR the DTCs. TEST the system for normal operation. If the DTC is repeated, INSTALL a new PCM. Before replacing a PCM, contact Dealer technical support.