P1532
Y: P1532. IMT VALVE 2
G92429t122 : CHECK THE POWER SUPPLY CIRCUIT TO THE IMT VALVE 2
1. Turn the ignition switch to the ON position.
2. Measure the voltage between IMT valve 2 electrical connector EN998 pin 1 (NG) and GROUND.
- Is the voltage greater than 10 volts?
-> Yes
-> No
REPAIR the circuit between the IMT valve 2 electrical connector EN998 pin 1 (NG) and the Battery power bus 2. CLEAR the DTC. TEST the system for normal operation.This circuit includes the power distribution fuse box and the EMS control relay.
G92429t123 : CHECK CONTINUITY OF THE IMT VALVE 2 SIGNAL WIRE
1. Disconnect the ECM electrical connector EN16.
2. Measure the resistance between the IMT valve 2 electrical connector EN998 pin 2 (OY) and the ECM electrical connector EN16 pin 39 (OY).
- Is the resistance less than 5 ohms?
-> Yes
-> No
REPAIR the circuit between the IMT valve 2 electrical connector EN998 pin 2 (OY)and the ECM electrical connector EN16 pin 39 (OY). CLEAR the DTC. TEST the system for normal operation.
G92429t163 : CHECK IMT VALVE SIGNAL WIRE FOR SHORT TO GROUND
1. Measure the resistance between EN998 pin 2 (OY) and GROUND.
- Is the resistance less than 10,000 ohms?
-> Yes
REPAIR the short to GROUND. CLEAR the DTC. TEST the system for normal operation.
-> No
G92429t164 : CHECK IMT VALVE SIGNAL WIRE FOR SHORT TO BATTERY
1. Connect the ECM electrical connector EN16.
2. Turn the ignition switch to the ON position.
3. Check for a voltage at EN998 pin 2 (OY).
- Is the voltage greater than 10 volts?
-> Yes
REPAIR the short to battery. CLEAR the DTC. TEST the system for normal operation.
-> No
INSTALL a new IMT valve. CLEAR the DTC. TEST the system for normal operation. If the DTC is repeated, INSTALL a new ECM. Before replacing an ECM, contact dealer technical support