P1629
D : GENERATOR LOAD MONITORING SIGNAL FAILURE (P1629)
G92604t13 : CHECK THE SIGNAL WIRE FOR OPEN CIRCUIT
1. Disconnect the ECM electrical connector EN16 and the generator electrical connector EN49.
2. Measure the resistance between electrical connector EN49-3 and the ECM electrical connector EN16-65.
- Is the resistance less than 5 ohms?
-> Yes
-> No
REPAIR the circuit from the ECM to the generator. CLEAR the DTC. TEST the system for normal operation.
G92604t14 : CHECK THE SIGNAL WIRE FOR A SHORT TO BATTERY POSITIVE
1. Measure the resistance between electrical connector EN49-3 and the generator battery positive cable.
- Is the resistance less than 10,000 ohms?
-> Yes
REPAIR short to the generator battery positive cable. CLEAR the DTC. TEST the system for normal operation.
-> No
G92604t15 : CHECK THE SIGNAL WIRE FOR A SHORT TO GROUND
1. Measure the resistance between electrical connector EN49-3 and ground.
- Is the resistance less than 10,000 ohms?
-> Yes
REPAIR the circuit from the ECM to the generator. CLEAR the DTC. TEST the system for normal operation.
-> No
INSTALL a new generator. CLEAR the DTC. TEST the system for normal operation. If the DTC is repeated, INSTALL a new ECM.