P0532
W : P0532, Air Conditioning Refrigerant Pressure Sensor Circuit Low Input
W1 : CHECK THE REFRIGERANT PRESSURE SENSOR CIRCUIT FOR SHORT TO GROUND
1. Disconnect the refrigerant pressure sensor electrical connector, FH110.
2. Measure the resistance between FH110, pin 003 (WU) and GROUND.
Is the resistance less than 10,000 ohms?
Yes
Repair the short to ground. For additional information, refer to wiring diagrams. CLEAR the DTC. TEST the system for normal operation.
No
Goto W2
W2 : CHECK THE REFRIGERANT PRESSURE SENSOR CIRCUIT FOR OPEN CIRCUIT
1. Disconnect the PCM electrical connector, PI001.
2. Measure the resistance between PI001, pin 121 (G) and the refrigerant pressure sensor electrical connector, FH110, pin 003 (G).
Is the resistance less than 5 ohms?
Yes
Goto Z. P1240
No
Repair the circuit. For additional information, refer to wiring diagrams. CLEAR the DTC. TEST the system for normal operation