B1851
B1851-FLIPPER GLASS SWITCH STUCK - CLUSTER
For a complete wiring diagram Consult Diagrams/Electrical.
- When Monitored:
Continuously
- Set Condition:
When the Cluster senses a low condition on the Flip-UP (Flipper) Glass Switch Sense circuit for over 10 seconds, this code will set.
Diagnostic Test
1. TEST FOR INTERMITTENT CONDITION
With the scan tool, record and erase DTC's
Operate the Flip-Up Glass Switch several times.
Cycle the ignition from on to off 3 times.
Turn the ignition on.
With the scan tool, read DTC's.
Does the scan tool display B1851-FLIPPER GLASS SWITCH STUCK?
Yes
- Go To 2
No
- The conditions that caused this code to set are not present at this time. Using the wiring diagram/schematic as a guide, inspect the wiring and connectors.
- Perform BODY VERIFICATION TEST - VER 1. Body Verification Test
2. FLIP-UP GLASS SWITCH STUCK
With the scan tool, erase DTC's.
Disconnect the License Lamp connector.
With the scan tool, read DTC's.
Does the scan tool display FLIPPER GLASS SWITCH STUCK?
No
- Replace the Flip-Up Glass Switch (License Lamp).
- Perform BODY VERIFICATION TEST - VER 1. Body Verification Test
Yes
- Go To 3
3. (Q80) FLIP-UP GLASS SWITCH SENSE CIRCUIT SHORT TO GROUND
Turn the ignition off.
Disconnect the Cluster C1 connector.
Measure the resistance between ground and the (Q80) Flip-Up Glass Switch Sense circuit.
Is the resistance below 1000.0 ohms?
Yes
- Repair the (Q80) Flip-Up Glass Switch Sense circuit for a short to ground.
- Perform BODY VERIFICATION TEST - VER 1. Body Verification Test
No
- Replace the Instrument Cluster.
- Perform BODY VERIFICATION TEST - VER 1. Body Verification Test