P0112
Intake Air Temperature Fault - Open Circuit.
P0112 - Intake Air temperature fault.: Last occurrence - minimum signal
Possible causes:
1. Short circuit C0606/34(YU) - battery.
2. Short circuit C0606/34 (YU) - 5 Volts.
3. Open circuit C0606/34 (YU) - C0149/1 (YU).
4. Short circuit C0606/9(B) - battery.
5. Short circuit C0606/9 (B) - 5 Volts.
6. Open circuit C0606/9 (B) - C0149/3 (B).
7. Connectors C0606, C0149.
8. Intake air temperature sensor.
1. Short circuit C0606/34(YU) - battery.
SHORT_CIRCUIT
Check resistance < 5.0 Ohms.
2. Short circuit C0606/34 (YU) - 5 Volts.
SHORT_CIRCUIT
Check resistance < 5.0 Ohms.
3. Open circuit C0606/34 (YU) - C0149/1 (YU).
OPEN_CIRCUIT
Check resistance > 1M Ohms.
4. Short circuit C0606/9(B) - battery.
SHORT_CIRCUIT
Check resistance < 5.0 Ohms.
5. Short circuit C0606/9 (B) - 5 Volts.
SHORT_CIRCUIT
Check resistance < 5.0 Ohms.
6. Open circuit C0606/9 (B) - C0149/3 (B).
OPEN_CIRCUIT
Check resistance > 1M Ohms.
7. Connectors C0606, C0149.
CONNECTOR
Check for connector not correctly latched, backed out pins, damaged pins, corroded pins
8. Intake air temperature sensor.
No detail available for this fault