P0113
Intake Air Temperature Fault - Short To Ground.
P0113 - Intake Air temperature fault.: Last occurrence - maximum signal
Possible causes:
1. Short circuit C0606/34 (YU) - ground.
2. Short circuit C0606/7 (RG) - ground.
3. Open circuit C0606/7 (RG) - C0149/4 (RG).
4. Connectors C0606, C0149.
5. Intake air temperature sensor.
1. Short circuit C0606/34 (YU) - ground.
SHORT_CIRCUIT
Check resistance < 5.0 Ohms.
2. Short circuit C0606/7 (RG) - ground.
SHORT_CIRCUIT
Check resistance < 5.0 Ohms.
3. Open circuit C0606/7 (RG) - C0149/4 (RG).
OPEN_CIRCUIT
Check resistance > 1M Ohms.
4. Connectors C0606, C0149.
CONNECTOR
Check for connector not correctly latched, backed out pins, damaged pins, corroded pins
5. Intake air temperature sensor
No detail available for this fault