P0131
O2 Sensor Circuit Bank 1 Upstream - Short To Ground.
P0131 - O2 sensor circuit bank 1 upstream sensor.: Last occurrence - minimum signal
Possible causes:
1. Short circuit C0606/19 (N) - ground.
2. Short circuit C0606/9 (Y) - ground.
3. Connectors C0606, C0642.
4. O2 Sensor.
1. Short circuit C0606/19 (N) - ground.
SHORT_CIRCUIT
Check resistance < 5.0 Ohms.
2. Short circuit C0606/9 (Y) - ground.
SHORT_CIRCUIT
Check resistance < 5.0 Ohms.
3. Connectors C0606, C0642.
CONNECTOR
Check for connector not correctly latched, backed out pins, damaged pins, corroded pins
4. O2 Sensor.
No detail available for this fault