P0140
O2 Sensor Circuit Bank 1 Downstream - Open Circuit.
P0140 - O2 sensor circuit bank 1 downstream sensor.: Last occurrence - signal fault
Possible causes:
1. Short circuit C0606/11 (YU) - C0643/3 (YU).
2. Connectors C0606, C0643.
3. O2 Sensor.
1. Short circuit C0606/11 (YU) - C0643/3 (YU).
OPEN_CIRCUIT
Check resistance > 1M Ohms.
2. Connectors C0606, C0643.
CONNECTOR
Check for connector not correctly latched, backed out pins, damaged pins, corroded pins
3. O2 Sensor.
No detail available for this fault