P0151
O2 Sensor Circuit Bank 2 Upstream - Short To Ground.
P0151 - O2 sensor circuit bank 2 upstream sensor.: Last occurrence - minimum signal
Possible causes:
1. Short circuit C0606/13 (NR) - ground.
2. Short circuit C0606/10 (YR) - ground.
3. Connectors C0606, C0645.
4. O2 Sensor.
1. Short circuit C0606/13 (NR) - ground.
SHORT_CIRCUIT
Check resistance < 5.0 Ohms.
2. Short circuit C0606/10 (YR) - ground.
SHORT_CIRCUIT
Check resistance < 5.0 Ohms.
3. Connectors C0606, C0645.
CONNECTOR
Check for connector not correctly latched, backed out pins, damaged pins, corroded pins
4. O2 Sensor.
No detail available for this fault