P0158
O2 Sensor Circuit Bank 2 Downstream - Short To Battery.
P0158 - O2 sensor circuit bank 2 downstream sensor.: Last occurrence - maximum signal
Possible causes:
1. Short circuit C0606/1 (NW) - battery.
2. Short circuit C0606/8 (YW) - battery.
3. Connectors C0606, C0642.
4. O2 Sensor.
1. Short circuit C0606/1 (NW) - battery.
SHORT_CIRCUIT
Check resistance < 5.0 Ohms.
2. Short circuit C0606/8 (YW) - battery.
SHORT_CIRCUIT
Check resistance < 5.0 Ohms.
3. Connectors C0606, C0642.
CONNECTOR
Check for connector not correctly latched, backed out pins, damaged pins, corroded pins
4. O2 Sensor.
No detail available for this fault