P0160
O2 Sensor Circuit Bank 2 Downstream - Open Circuit.
P0160 - O2 sensor circuit bank 2 downstream sensor.: Last occurrence - signal fault
Possible causes:
1. Short circuit C0606/8 (YW) - C0642/3 (YW).
2. Connectors C0606, C0642.
3. O2 Sensor.
1. Short circuit C0606/8 (YW) - C0642/3 (YW).
OPEN_CIRCUIT
Check resistance > 1M Ohms.
2. Connectors C0606, C0642.
CONNECTOR
Check for connector not correctly latched, backed out pins, damaged pins, corroded pins
3. O2 Sensor.
No detail available for this fault