Operation CHARM: Car repair manuals for everyone.

P0160



O2 Sensor Circuit Bank 2 Downstream - Open Circuit.

P0160 - O2 sensor circuit bank 2 downstream sensor.: Last occurrence - signal fault

Possible causes:
1. Short circuit C0606/8 (YW) - C0642/3 (YW).
2. Connectors C0606, C0642.
3. O2 Sensor.

1. Short circuit C0606/8 (YW) - C0642/3 (YW).
OPEN_CIRCUIT
Check resistance > 1M Ohms.

2. Connectors C0606, C0642.
CONNECTOR
Check for connector not correctly latched, backed out pins, damaged pins, corroded pins

3. O2 Sensor.
No detail available for this fault