Operation CHARM: Car repair manuals for everyone.

P0615



Comfort Start Output Drive - Open Circuit.

P0615 - Comfort start output drive fault.: Last occurrence - signal fault

Possible causes:
1. Open circuit C0606/12 (BG) - C0179/1 (BG).
2. Connectors C0606, C0179.
3. Starter motor relay.

1. Open circuit C0606/12 (BG) - C0179/1 (BG).
OPEN_CIRCUIT
Check resistance > 1M Ohms.

2. Connectors C0606, C0179.
CONNECTOR
Check for connector not correctly latched, backed out pins, damaged pins, corroded pins

3. Starter motor relay.
RELAY
Check for relay not correctly seated, backed out pins, damaged pins, corroded pins, relay coil open circuit, faulty relay contacts, ensure power & ground feeds to relay coil are present and that the relay is energised.