Operation CHARM: Car repair manuals for everyone.

P1527



VANOS Bank 2 Output Drive - Short To Ground.

P1527 - VANOS bank 2 output drive fault.: Last occurrence - minimum signal

Possible causes:
1. Short circuit C0606/29 (GS) - ground.
2. Connectors C0606, C2317.
3. VANOS actuator bank 2
4. V8 Engine Management System ECM.

1. Short circuit C0606/29 (GS) - ground.
SHORT_CIRCUIT
Check resistance < 5.0 Ohms

2. Connectors C0606, C2317.
CONNECTOR
Check for connector not correctly latched, backed out pins, damaged pins, corroded pins

3. VANOS actuator bank 2
No detail available for this fault

4. V8 Engine Management System ECM.
No detail available for this fault