Pressure Regulator Monitoring (S/C to Ground or O/C)
DTC P0748
Pressure regulator monitoring (S/C to Ground or O/C).
Possible causes by suggested order of priority:
^ Short circuit C193/5 (G) to vehicle earth.
^ Open circuit C193/5 (G) to C193/53 (OLG).
^ Short circuit C193/53 (OLG) to vehicle earth.
^ Faulty EAT(gearbox) ECU
Short Circuit C193/5 (G) To Vehicle Earth.
SHORT_CIRCUIT
^ Check resistance < 5.0 ohms
Open Circuit C193/5 (G) to C193/53 (OLG).
CHECK THE FOLLOWING:
^ Open circuit, check resistance C193/5 (G) to C193/53 (OLG).
ACCEPTABLE RANGE
> 50 Ohms.
DIAGNOSTIC HINTS
^ If the reading is not within the acceptable range check for open circuit:
C193/5 (G) to C243/B (G).
Or
C193/5 (G) to C243/M (OLG).
Short Circuit C193/53 (OLG) To Vehicle Earth.
SHORT_CIRCUIT
^ Check resistance < 5.0 ohms
Faulty EAT(gearbox) ECU
CHECK THE FOLLOWING:
^ Ensure all of the checks for short to vehicle earth or open circuit have been carried out.
^ If these problems are not present check transmission ECU by substitution with a known good unit.
POSSIBLE FAULTS
^ Faulty transmission ECU.