P0052
Oxygen Sensor Heater Pre Bank 2 Short To Supply
P0052 - Pre-catalyst oxygen sensor heater bank 2.: Short circuit to V Batt.
Possible causes:
1. Short circuit C645/4 (GY) - Supply.
2. Oxygen sensor pre catalyst bank 2.
3. MS43 ECM.
1. Short circuit C645/4 (GY) - Supply.
PASS VALUES: 0 - 6 Volts
2. Oxygen sensor pre catalyst bank 2.
No detail available for this fault
3. MS43 ECM.
No detail available for this fault