P0058
Oxygen Sensor Heater Post Cat Bank 2 Short To Supply
P0058 - Post catalyst oxygen sensor heater bank 2.: Short circuit to V Batt.
Possible causes:
1. Short circuit C642/4 (UY) - Supply.
2. Oxygen sensor post catalyst bank 2.
3. MS43 ECM.
1. Short circuit C642/4 (UY) - Supply.
PASS VALUES: 0 - 6 Volts
2. Oxygen sensor post catalyst bank 2.
No detail available for this fault
3. MS43 ECM.
No detail available for this fault