P0102
Airflow Sensor Signal Line Open Circuit Or Short To Ground
P0102 - Air flow meter.: Short circuit to ground.
Possible causes:
1. Connector MS43 ECM C606, Airflow sensor C149.
2. Open circuit C606/1 (GW) - C149/2 (GW).
3. Short circuit C149/2 (GW) - Ground.
4. Airflow sensor.
5. Open circuit C149/3 (YG) - C578/11 (YG).
6. MS43 ECM.
1. Connector MS43 ECM C606, Airflow sensor C149.
CONNECTOR
Check for connector not correctly latched, backed out pins, damaged pins, corroded pins
2. Open circuit C606/1 (GW) - C149/2 (GW).
OPEN_CIRCUIT
Check resistance > 1M Ohms.
3. Short circuit C149/2 (GW) - Ground.
SHORT_CIRCUIT
Check resistance < 5.0 Ohms.
4. Airflow sensor.
No detail available for this fault
5. Open circuit C149/3 (YG) - C578/11 (YG)
OPEN_CIRCUIT
Check resistance > 1M Ohms.
6. MS43 ECM.
No detail available for this fault