P0130
Oxygen Sensor Pre Cat Bank 1 Open Circuit
P0130 - Oxygen sensor pre-catalyst bank 1.: Open circuit or No signal.
Possible causes:
1. Connector MS43 ECM C604, Oxy Sensor Pre Cat Bank 1 C644, Engine Fusebox C578.
2. Open circuit C604/14 (UN) - C644/2 (UN).
3. Open circuit C604/20 (BG) - C644/1 (BG).
4. Oxygen sensor pre catalyst bank 1.
5. MS43 ECM.
1. Connector MS43 ECM C604, Oxy Sensor Pre Cat Bank 1 C644, Engine Fusebox C578.
CONNECTOR
Check for connector not correctly latched, backed out pins, damaged pins, corroded pins
2. Open circuit C604/14 (UN) - C644/2 (UN).
OPEN_CIRCUIT
Check resistance > 1M Ohms.
3. Open circuit C604/20 (BG) - C644/1 (BG).
OPEN_CIRCUIT
Check resistance > 1M Ohms.
4. Oxygen sensor pre catalyst bank 1.
No detail available for this fault
5. MS43 ECM.
No detail available for this fault