P0267
Injector Cylinder 3 Power Stage Short Circuit To Ground
P0267 - Injector power stage cylinder 3.: Short circuit to ground.
Possible causes:
1. Short circuit C606/34 (YU) - Ground.
2. Injector 3.
3. MS43 ECM.
1. Short circuit C606/34 (YU) - Ground.
SHORT_CIRCUIT
Check resistance < 5.0 Ohms.
2. Injector 3.
No detail available for this fault
3. MS43 ECM.