P1135
Oxygen Sensor Pre Bank 1 Rich To Lean Response Time Excessive
P1135 - Oxygen sensor response time bank 1.: Open circuit or No signal.
Possible causes:
1. Oxygen sensor pre catalyst bank 1.
1. Oxygen sensor pre catalyst bank 1.
CHECK THE FOLLOWING:
- If the heater for this oxygen sensor has a fault recorded for it, this could have affected the operation of the oxygen sensor. Rectify any heater fault first.
- Remove the oxygen sensor and examine the side internal to the exhaust system and the side outside the exhaust system. Both sides of the sensor should be free from contamination. Gas must be able to be absorbed by both sides of the sensor.
- Also check the sensor for any mechanical damage or cracks.
INFORMATION
- If the oxygen sensor shows signs of damage or contamination that cannot be cleaned it should be renewed.