P1475
Variable Inlet Manifold Bank 1 Output Open Circuit Or Short To Ground
P1475 - Variable inlet manifold motor 1.: Open circuit or No signal.
P1475 - Variable inlet manifold motor 1.: Short circuit to ground.
Possible causes:
1. Connector MS43 ECM C606, Variable intake motor bank 1 C972, Engine fusebox C578.
2. Open circuit C606/11 (SB) - C972/1 (SB).
3. Short circuit C606/11 (SB) - Ground.
4. Variable intake manifold motor bank 1.
5. MS43 ECM.
1. Connector MS43 ECM C606, Variable intake motor bank 1 C972, Engine fusebox C578.
CONNECTOR
Check for connector not correctly latched, backed out pins, damaged pins, corroded pins
2. Open circuit C606/11 (SB) - C972/1 (SB).
OPEN_CIRCUIT
Check resistance > 1M Ohms.
3. Short circuit C606/11 (SB) - Ground.
SHORT_CIRCUIT
Check resistance < 5.0 Ohms.
4. Variable intake manifold motor bank 1.
No detail available for this fault
5. MS43ECM
No detail available for this fault