P1689
Brake Vacuum Enhancer Output Short Circuit To Supply
P1689 - Brake vacuum enhancer solenoid.: Short circuit to V Batt.
Possible causes:
1. Short circuit C1977/1 (BS) - Supply.
2. Brake servo vacuum pump unit.
3. MS43 ECM.
1. Short circuit C1977/1 (BS) - Supply.
PASS VALUES: 0 - 6 Volts
2. Brake servo vacuum pump unit.
No detail available for this fault
3. MS43 ECM.
No detail available for this fault